ROSE Testing System
SCS
Omegameter SMD 650
Ionic Contamination Testing System
for Printed Circuit Boards and Assemblies
Overview
From SCS, the name synonymous with automated ROSE (Resistivity of Solvent Extract) testing systems, comes SCS Omegameter — an industry standard for accurate, efficient and practical quality assurance testing. Being the first test system on the market, the SCS Omegameter SMD 650 has become the preferred choice for ionic testing utilizing the "static test" methodology. It performs cleanliness testing on printed circuit boards and assemblies using a heated, agitated extract solution that accurately measures contamination — that which is often the result of fabrication and board assembly processes. With the SCS Omegameter SMD 650, manufacturers benefit from an effective and practical quality assurance tool for a wide range of commercial applications.
Features & Benefits
- Self-contained system
- Simple, user-friendly operation
- Heated test solution for improved solubility of contaminants per IPC-TM-650
- Submerged spray jets in test cell for increased contamination removal
- Storage of up to 99 test profiles
- Near infinite memory for test data storage with optional software
- Rapid pumping rate of test solution
- Multiple test cell assembly sizes
Technical Specifications
| Test Cell Assembly Options | 8 x 8 in / 20.3 x 20.3 cm 12 x 12 in / 30.5 x 30.5 cm 12 x 18 in / 30.5 x 45.7 cm 18 x 18 in / 45.7 x 45.7 cm 26 x 26 in / 66.0 x 66.0 cm |
|---|---|
| Solution Capacity | 10 gal / 37.9 L |
| Dimensions (W x D x H) | 43 x 29 x 54 in / 109.2 x 73.7 x 137.2 cm (with 26 x 26 in test cell) |
| Power Input | 220 VAC ±10%, 50/60 Hz, 6.5A |
| Weight | 252 lb / 114 kg |